RAYSONHIGH PERFORMANCE COATINGSMALAYSIA
Rayson SealForce · Acrylic

Rayson SealForce AP05

Rayson SealForce AP05 is a one-part, water-based acrylic primer for the SealForce waterproofing range — brushed or rolled onto concrete, render, brick, stone and roof tiles to seal pores, bind dust and give SealForce AC10 a firm surface to bond to.

RoofsWallsConcrete TDS RY-TDS-1107
Rayson SealForce AP05 pail
Best for

Best for absorbent, dusty or smooth surfaces on roofs and external walls — concrete, render, brick, stone and unglazed or clay tiles — before the SealForce AC10 acrylic membrane goes on.

SealForce AP05 is the first coat of Rayson's acrylic roof and wall system: a milky-white acrylic dispersion in water, stirred and applied straight from the pail by brush or roller. It soaks into the surface, binds loose dust, firms weak surface layers and seals the pores, then dries to a clear film — the change from white to clear shows when it is ready for the membrane.

It does three jobs under SealForce AC10. On smooth, dense concrete it acts as a bonding primer; on rough, porous concrete it seals the pores so air cannot rise through the wet membrane as bubbles and pinholes; and on brick, stone and old tiles it consolidates the surface so the membrane bonds to sound material rather than dust. Very porous surfaces take a second coat.

It is a primer, not a waterproofing layer, and it must always be covered by the membrane. It belongs to the water-based acrylic system: SealForce WB20 needs no primer, and the polyurea membranes, SealForce RC40, RC30, SP200 and SP210, each take the primer named in their own data sheets.

In Malaysia

Supplied by Epovex Coatings Sdn. Bhd., Company No. 202601042128 (1704223-A). The Malaysia launch is scheduled for 1 March 2027; confirm availability and lead time for your project. Installation through an authorised applicator in Johor, Kuala Lumpur or Penang introduced by Rayson, who quotes and warrants the workmanship, or by your own crew with Rayson’s application guidance.

Send an enquiry

Key benefits

  • One-part and water-based — stirred and applied straight from the pail by brush or roller
  • Improves the bond of SealForce AC10 to concrete, render, masonry and tiles
  • Seals pores so the membrane cures without bubbles or pinholes
  • Binds surface dust and firms weak surface layers
  • Goes on milky white and dries clear, so it is easy to see when it is ready to coat

Recommended uses

  • Primer for absorbent concrete, render, brick, stone and tiles before SealForce AC10
  • Bonding primer on smooth, dense concrete finishes
  • Binding surface dust and firming weak surface layers before the membrane
  • Sealing pores in rough concrete so the membrane cures without bubbles or pinholes

Application

  1. Brush
  2. Roller
SpecificationData sheet value
CoverageApproximately 0.1–0.3 kg/m² per coat, depending on absorbency; a 20 kg pail primes about 65–200 m² per coat. Very porous surfaces take a second coat
MixingOne part, ready to use — stir for at least 1 minute with a slow paddle until uniform, without whipping in air
Drying and curingDry when the milky white has turned clear — about 30 minutes, longer in cool or humid weather. Apply SealForce AC10 once it has dried clear. Protect from rain until dry
Pack sizes20 kg pail

Typical systems

Concrete or rendered roof and wall, before SealForce AC10

  1. Prepare the surface mechanically; repair cracks, voids and spalls with Rayson PatchBond TX80 and let the repairs cure
  2. Vacuum all dust; the surface must be dry, with no standing water
  3. Apply one coat of Rayson SealForce AP05 at about 0.1–0.3 kg/m² by brush or roller; a second coat on very porous concrete
  4. When it has dried clear, about 30 minutes later, apply Rayson SealForce AC10

Old roof tiles, brick or stone, before SealForce AC10

  1. Fix loose tiles or units, replace broken or missing ones and point open mortar joints
  2. Power-wash the surface and allow it to dry
  3. Apply one coat of Rayson SealForce AP05 at about 0.1–0.3 kg/m²
  4. When it has dried clear, apply Rayson SealForce AC10 in two coats

Limitations

  • A primer, not a waterproofing layer: always cover it with SealForce AC10
  • Apply between +5 °C and +40 °C, at no more than 80% relative humidity, with the substrate at least 3 °C above the dew point
  • Substrate moisture at most 6% by weight; no standing water and no rising moisture
  • Protect from rain until dry
  • Not for use under the polyurea membranes — SealForce RC40, RC30, SP200 and SP210 take the primer named in their own data sheets
  • Metal needs an anti-corrosion primer instead; on glazed tiles, sound old coatings or other dense surfaces, confirm adhesion with a trial area first

Not suitable for

  • Floors under water-based urethane finishes — use Rayson PrimeBond W10
  • Under the polyurea membranes SealForce RC40, RC30, SP200 and SP210
  • Under SealForce WB20 in toilets and bathrooms, which needs no primer
  • Use on its own as a sealer or finish — it must be covered by SealForce AC10

Used with

Jobs across Malaysia

Jobs that use Rayson SealForce AP05

Rayson-authorised applicators in Johor, Kuala Lumpur and Penang install Rayson SealForce AP05 on these jobs; its layer is marked in each build-up. You can also order it direct and apply it yourself, with the step-by-step guide. Each page shows how the work runs, what to send for a quotation and what decides the price.

Order it direct, with a step-by-step guide

01 Rayson system Layers: SealForce AC10, two coats, fleece at moving cracks; SealForce AP05 primer; Roof, render or old roof tiles, sound and dry

Waterproof coating

SealForce AC10 acrylic, RC40 polyurea and WB20 wet-area membrane, sold direct with the coverage and a step-by-step guide.

  1. SealForce AC10, two coats, fleece at moving cracks
  2. SealForce AP05 primer
  3. Roof, render or old roof tiles, sound and dry

Flat roofs and decks that are walked on: SealForce RC40 polyurea. Toilets, under the tiles: SealForce WB20.

Quoted per order

Jobs in Johor

02 Rayson system Layers: SealForce AC10 acrylic roof membrane; SealForce AP05 primer; Roof slab, cracks repaired

Roof leak repair

Flat concrete, tiled and metal roofs: the cause found first, then a membrane over the whole roof.

  1. SealForce AC10 acrylic roof membrane
  2. SealForce AP05 primer
  3. Roof slab, cracks repaired

Flat roofs that pond or are walked on: SealForce RC40 polyurea.

Quoted after inspection
03 Rayson system Layers: SealForce AC10 on the external face; SealForce AP05 primer; Render with SealForce RW1, cracks filled; Brick or block wall

Wall seepage and crack repair

Damp, peeling, mouldy walls: rain through the render, rising damp or a leak next door.

  1. SealForce AC10 on the external face
  2. SealForce AP05 primer
  3. Render with SealForce RW1, cracks filled
  4. Brick or block wall

Water from a wet area behind the wall: that room is re-waterproofed instead.

Quoted after inspection
04 Rayson system Layers: SealForce RC40 polyurea on exposed concrete roofs; Primer to the data sheet; Roof slab, laps, gutters and penetrations detailed

Factory and warehouse roof waterproofing

Large flat and metal roofs in Johor’s industrial parks, coated without stopping production.

  1. SealForce RC40 polyurea on exposed concrete roofs
  2. Primer to the data sheet
  3. Roof slab, laps, gutters and penetrations detailed

Metal and free-draining roofs: SealForce AC10, over an anti-corrosion primer on metal or AP05 on concrete.

Quoted after inspection

Jobs in Kuala Lumpur and Selangor

Kuala Lumpur and Selangor ↗
05 Rayson system Layers: SealForce RC40 polyurea, details first, then the whole roof; Primer to the data sheet, fleece at moving cracks; Flat or porch-roof slab, cracks and falls repaired

Roof and ceiling leak repair in KL and Selangor

Flat roofs, porch roofs, tiled roofs and factory metal roofs in the Klang Valley: the leak traced, then the Rayson membrane that suits the roof.

  1. SealForce RC40 polyurea, details first, then the whole roof
  2. Primer to the data sheet, fleece at moving cracks
  3. Flat or porch-roof slab, cracks and falls repaired

Roofs that drain freely and old roof tiles: SealForce AC10 over AP05 primer. Metal roofs: AC10 over an anti-corrosion primer, with fleece at the laps.

Quoted after inspection
The practical details

Rayson SealForce AP05: questions people ask

What is SealForce AP05 used for?

It prepares concrete, render, brick, stone and roof tiles for SealForce AC10, the acrylic roof and wall membrane: a bonding primer on smooth concrete, a pore sealer on rough concrete, and a dust binder on weathered masonry and tiles. It is brushed or rolled on, dries clear and is always covered by the membrane.

Which Rayson waterproofing membranes need it?

SealForce AC10, on concrete, render, brick, stone and tiles. SealForce WB20 does not: it goes straight onto the prepared screed or concrete of a toilet or bathroom. The polyurea membranes, SealForce RC40, RC30, SP200 and SP210, each take the primer named in their own data sheets, not AP05. Metal under AC10 takes an anti-corrosion metal primer.

How much do I need?

About 0.1 to 0.3 kg/m² per coat, depending on how absorbent the surface is; a 20 kg pail primes about 65 to 200 m² per coat. Very porous concrete, brick or tiles take a second coat, and a small test area shows the real figure for each surface.

How long before the membrane goes on?

Until the milky white has turned completely clear: about 30 minutes, longer in cool or humid weather. Then apply SealForce AC10, cleaning off any dust that has settled first. Protect the primer from rain until it is dry.

Can it go on old roof tiles, brick or stone?

Yes, once the surface is sound: loose tiles or bricks fixed, broken ones replaced, open joints pointed, and the surface power-washed and dried. It suits unglazed ceramic and clay tiles; on glazed tiles or other dense surfaces, a trial area confirms adhesion first.

SealForce AP05 or PrimeBond W10: what is the difference?

Both are one-part, water-based acrylic primers, for different systems. AP05 is the SealForce waterproofing primer for roofs and external walls under SealForce AC10. PrimeBond W10 is the floor primer under Rayson's low-odour water-based urethane finishes, such as UraForce WB52.

Can it be left on its own as a sealer?

No. It binds dust and seals pores ahead of the membrane, but it is not a waterproofing layer or a wearing surface. It must be covered by SealForce AC10.

Is SealForce AP05 available to order now?

SealForce AP05 is part of Rayson's upcoming waterproofing release, alongside SealForce AC10. Send the project details and your required date, and Rayson will confirm supply timing, quantities and, where you need one, an applicator in the Rayson network before you commit.

Start a conversation / ↗

Send the job, or ask for materials

Tell us what the surface is, where it is and what it has to withstand. Rayson replies with a system recommendation; for installation, the applicator for your area in Johor, Kuala Lumpur or Penang is introduced to quote the job.

Malaysia launch: 1 March 2027. Enquiries are welcome now; supply, site assessment and installation timing are confirmed for each project.

Thank you. Your enquiry has been received and we reply within one working day, Monday to Friday.

WhatsApp